Kitchen Waterproofing
NANOFIX RECOMMENDS FOLLOWING PRODUCTS FOR YOUR KITCHEN
Nanofix Flexeet Part A & B :
Nanofix Flexeet is used for high strength forming stone like barrier to stop damp & leak patches appearing under water pressure.
Nanofix PU Sealant :
Nanofix PU Sealant is flexible in nature & it is used to seal the surface cracks, annular gaps of the pipes and wall-slab junction.
Nanofix 0102 :
Nanofix 0102 can be used on damp affected areas or wet surface & can be handled in any temparature. It is very easy to apply over a wide range of substrate. It has good bonding with screed concrete or bedding mortar on top.
NANOFIX Methodology for Kitchen Waterproofing
Nanofix Flexeet Part A & B
Surface to be made wet by sprinkling of water before the application of first coat. Nanofix –Flexeet. 1 Part A & 1 Part B should be taken by weight in one container and mixed properly. Then slowly add 1 part of water into the mix & stir it thoroughly to get a homogeneous mixture. Application should be uniform by brush leaving no gap on top of the concrete surface and vertically up to a height of 300 MM. The ready mixture is to be applied within 10 to 15 minutes, so it is advised to take smaller quantity of product at a time. After 24 hours, 2nd coat to be applied maintain the same ratio as mention above for 1st coat & immediate sand blasting on the treatment for better bonding with screed concrete which is to be laid on it. After curing, checking the treatment by stand pool of water. Top covering by floor tiles or screed concrete maintaining proper slope.
Nanofix 0102
Surface to be made wet by sprinkling of before the application of first coat. Nanofix 0102 should be applied by brush leaving no gaps on top of the concrete surface and vertically up to the skirting height of 300mm. After drying of first coat, 2nd coat to be applied. Mix ratio –1 Litre material to be mix with 2 litre of water & approx 1.2 to 1.5 kgs cement is added to prepare homogeneous slurry. The treated surface should be left for curing for at least one day. After curing, checking the treatment by stand pool of water. Top covering by floor tiles or screed concrete maintaining proper slope.
Nanofix PU Sealant
Seal the minor cracks, the joint between wall and R.C.C. slab & annular gap of pipes with PU Sealant and to flash at both the end.
FAQ :
Q. What is the need for Kitchen waterproofing?
A Kitchen not waterproofed can ruin interiors, hassle residents, and incur significant repair costs in the future.
Q. What are the precautions to be taken to avoid leakages in Kitchen?
It is essential that water used in Kitchen is drained out only through the pipes
For detail specification & assistance as per your need, please contact our technical division.
Material Handling & Safety Information :
- Nanofix product should be stored in closed container in a cool, dry place away from direct sunlight
- Maintain safety during execution of the waterproofing jobs and due care to be taken while handling Nanofix & other construction materials.
- Nanofix materials are nontoxic. Hands and tools should be washed with normal water.
- NANOFIX recommends the enforcement of stringent health and safety measures at all job sites.